A full range of small-footprint, fiber optic spectrometers covering 150 - 2500 nm with FWHM resolution starting at 0.1 nm
 
Solar resistant, UV/VIS and VIS/NIR fibers with a range of jacketing and termination options
 
Driver platforms for embedded and other system designs supporting Windows, Mac OS and Linux
 
O2 and pH sensors for both aqueous and atmospheric applications
 
For use with the S2000 and multi-channel systems
 

An analog-to-digital converter is necessary to interface all Ocean Optics spectrometers to PCs. Using the ADC1000-USB to interface the spectrometer to a PC eliminates the need for installing A/D converters into a PC’s motherboard and for searching for available IRQs and I/O ranges. Instead, the ADC1000-USB connects to the back of an S2000-series Spectrometer and connects to a notebook or desktop PC via a 1-meter USB cable (included). Additionally, the ADC1000-USB can be stacked or rack-mounted with the spectrometer in the same housing.

  • Versatile Interface Options. Allows you to interface the spectrometer to a desktop, notebook or handheld PC via the USB port or to a PLC via the serial (RS-232) port

  • Multiple Setup Options. The ADC-1000 USB can be attached directly to the back of an S2000-series Spectrometer or stacked or rack-mounted with the spectrometer in the same housing

  • 1 MHz Sampling Frequency. Enables spectrometer integration times as fast as 3 milliseconds

  • Channel Rotator Function. Allows simultaneous acquisition of data from up to 8 spectrometer channels

  • No External Power Requirements. When the USB port is utilized, the spectrometer and ADC1000-USB draw their power from the computer to which they are connected

Serial Interface Option

The ADC1000-USB also has a serial port for interfacing the spectrometer to PCs, PLCs and other devices that support the RS-232 communication protocol. When using the serial port on the ADC1000-USB, a separate serial cable and power supply must be specified, as they are not included with the ADC1000-USB. The serial port on the ADC1000-USB can also be used to interface an S2000 to a handheld PC running Windows CE 3.0. A different serial cable is required for spectrometer-to-handheld PC interfacing.

Storing Wavelength Calibration Coefficients

Each spectrometer has unique wavelength calibration coefficients that are necessary for calibrating the wavelength of the spectrometer. With the ADC1000-USB, you can permanently store these values onto an EEPROM memory chip in the ADC1000-USB.

High-speed Data Processing

The ADC1000-USB has 1 MHz sampling frequency for high-speed data processing. Because the integration time of Ocean Optics spectrometers is a function of each A/D converter's sampling frequency, the fastest S2000 Spectrometer integration time possible with the ADC1000-USB is 3 milliseconds, well within the parameters required for most applications. (At the opposite extreme, the longest possible integration time is 60 seconds.)

Channel Rotator Function

The ADC1000's channel rotator permits acquisition of pixels from alternating channels. For example, acquisition with a triple-channel spectrometer can be configured so that Pixel #0 is acquired from the master channel, Pixel #1 is acquired from the first slave channel, and Pixel #2 from the second slave channel. As the sequence repeats, Pixel #3 is acquired from the master channel, and so on. As a result, spectra are acquired from multiple spectrometer channels simultaneously, making the ADC1000 ideal for applications involving pulsed light sources and transient spectral events. The data collected when using the multi-channel scanning capability of the ADC1000-USB can be separated into individual spectra by a variety of Ocean Optics software products.

Operating Systems

When using the USB port on the ADC1000-USB to interface the spectrometer to a desktop or notebook PC, you must have a Windows 98/Me/2000/XP operating system. Using the serial port on the ADC1000-USB to interface the spectrometer to a desktop or notebook PC requires any 32-bit Windows operating system.

Dimensions: 105.83 mm x 104.87 mm x 41.07 mm 
Weight: 230 grams
Integration time: 3 milliseconds to 60 seconds (when used with S2000 Spectrometers)
Data transfer rate:
  • Via USB port, full scans (2048 wavelengths) into memory every 13 milliseconds
  • Via RS-232, full scans into memory every 300 milliseconds
Board architecture/design: USB and RS-232 interfaced external A/D board
A/D resolution: 12-bit
Channels: 8
Sampling frequency: 1 MHz (maximum)
Computer interface:
  • Universal Serial Bus
  • RS-232. If interfacing the ADC1000-USB to a PC via the serial port located on the back of the unit, an additional serial cable and an external +5V AC power supply are required
Operating system requirements:
  • Windows 98/Me/2000/XP operating system when using the USB interface on desktop or notebook computers
  • Any 32-bit Windows operating system when using the serial port on desktop or notebook computers
  • Windows CE 3.0 operating system when using the serial port on handheld computers
Interface cable:
  • Comes with a 1-meter-long cable for connecting the ADC1000-USB to a USB port in a PC
  • Cable for connecting the ADC1000-USB to a serial port in a PC is not included but is available (item ADC-USB-SER)
Multiple-channel capability: Up to 8 spectrometer channels for S2000 Spectrometers
Spectrometer compatibility: Supports S2000 and S1024DW Spectrometers 
Software compatibility: Supports all 32-bit Ocean Optics software
 

 

 
 

Contact us: +1 727-733-2447 | oem@oceanoptics.com
Contents and images are Copyright Ocean Optics, Inc. 2009 or used by permission.
All logos and product names used are trademarks of Ocean Optics, Inc. All rights reserved.